Product ParametersParameter DescriptionRemark
 

 

 

Contamination Ratio

Dual sensor value 50~100%
Measurement range 90~100%Measurement accuracy ±1%+ 1%FS of reading
Measurement range 80~90%Measurement accuracy ±2%
 

Contamination Ratio Measurement Accuracy

 

Measurement range 50~80%

Measurement accuracy ±5%, Processed by internal sophisticated

algorithms

StabilityBetter than full range by 1% (per year)
 

Backplane Temperature Sensor

Measurement range: -50~150°C Accuracy: 0.2°C

Resolution: 0.1°C

 

Optional

 

GPS Positioning

Operating voltage: 3.3V-5V Operating current: 40-80mA Positioning accuracy: Average 10m 

Optional

 

 

Output Method

RS485 Modbus
Linked Output (Passive Normally Open Contact)Generally used to connect cleaning equipment, relay
Alarm thresholdUpper and Lower Thresholds Can Be Set
Operating voltageDC12V(Permissible Voltage Range DC9~30V)
Current range70~200mA @DC12V
Maximum power consumption<2.5W@DC12VLow power design
Operating temperature-40°C ~ +60°C
Operating humidity0 ~ 90%RH
Weight3.5KgNet weight
Dimensions900mm*170mm*42mmNet size
Sensor cable length20m